Moisture Sensor or Compressor and Outlet Thermistors Error
F3-E5
Moisture Sensor 2 (rear) Open/Shorted (only Quad Sense models)
WED99HEDW0 WED99HEDC0 – Indicates that the Compressor and Outlet Thermistors are open.
Whirlpool Dryer F3-E5 Error Code Error Code Possible Causes
- The moisture sensor is defective.
- The main PCB is defective.
- Loose wiring connection at the moisture sensor or main PCB.
WED99HEDW0 WED99HEDC0
- P14 connector is not plugged into the CCU.