Diverter Error
Drain Error
F9-E2
The diverter motor is stuck on.
24″ Microfiltration Dishwashers (square sump) – Drain motor electrical problem.
Whirlpool Dishwasher F9-E2 Error Code Error Code Possible Causes
- The diverter valve is defective.
- The diverter valve position switch is defective.
- Loose wire connectors.
- The main PCB is defective.
24″ Microfiltration Dishwashers (square sump)
- The drain pump is defective.
- The Main PCB is defective.
- Loose wire connectors.
KitchenAid and Maytag 24″ Microfiltration Dishwashers
- The water supply valve is defective.
- The water supply valve is not connected to the wire harness.
- The main PCB defective.