Meat Probe Error
E116
Cavity 1 meat probe error. “Hot” wire shorted to ground. Connection to the probe changes from connected to disconnected multiple times. Probe is disabled, but oven continues to operate. Error will be cleared and probe enabled after a control reset. Standard probe assembly is part of the control module; see Communication Schematic
Bosch Oven E116 Error Code Error Code Possible Causes
- The meat probe receptacle is defective.
- The oven control PCB is defective.
- Wiring issue.