Door Latch Error
E106
Cavity 1 latch operation not determined by control module. Door latch does not lock after 1 minute and further attempts will stop. Error will be cancelled and normal operation resumed if a locked door is no longer required. See Cavity 1 (upper) Small Load Schematic
Bosch Oven E106 Error Code Error Code Possible Causes
- The control module is defective.
- One of the door latch switches are defective.
- Wiring issue between the door switches and the relay board.