Thermistor Error
E oP
Open Thermistor Error. Physical open in the thermistor circuit.
When control senses temperature less than 0
°F after first three minutes of active cycle, will go to Cool Down, display error message, and turn on audio signal. Error message will continue until any keypads are pressed, Cool Down cycle has ended, and temperature reading is greater than 0°F. Once all three occur, control will return to Idle Mode.
Alliance Dryer E oP Error Code Error Code Possible Causes
- The thermistor is defective.
- The main PCB id defective.
- Loose wiring connection at the thermistor or main PCB.