The UltraFresh Vent LED may remain on when the LED is expected to turn off. 1. When the power button is used to turn on the washing machine. 2. When the UltraFresh Vent cycle is selected and then attempt to cancel the cycle by turning the knob. 3. Starting an UltraFresh Vent cycle, but the cycle does not start.
GE Washer Service Bulletins
GE Washer TB04-23 Service Bulletin
When leaving the dispenser drawer open to dry in-between cycles, the drawer is recommended to be opened greater than 1” to ensure the bulk dispenser is fully disengaged from the bulk dispense port. If the drawer if left open less than a 1”, detergent may leak onto the tub gasket, as shown below, or from the bottom of the door.
GE Washer PTLC22013 Service Bulletin
Change the Askoll drain pump
GE Washer TB29-22 Service Bulletin
Mode Shifter Circuit Testing Techniques
GE Washer PTLC22012 Service Bulletin
Change the Askoll drain pump
GE Washer PTLC22011 Service Bulletin
Dispenser drawer won’t seat or falls out
GE Washer PTLC22010 Service Bulletin
Laundry center will not start-up, lid lock does not activate, unit does not fill, spin, or complete cycles
GE Washer PTLC22007 Service Bulletin
Double Supply Nut Hub
GE Washer PTLC22004 Service Bulletin
Top Load Laundry and Laundry Centers Subject: Agitator or Spin Basket Seized to Transmission Shaft
GE Washer PTLC22003 Service Bulletin
Dual action agitator auger disengaged from base